Product Details
Place of Origin: China
Brand Name: Bosch Rexroth
Certification: GS, RoHS, CE, ISO9001
Model Number: A4VSG
Payment & Shipping Terms
Minimum Order Quantity: 1pc
Price: negotiated
Packaging Details: wooden carton
Delivery Time: 5-8 work days
Payment Terms: D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 50 pcs / month
Series: |
1x And 3x |
Sizes: |
40 To 1000 |
Nominal Pressure: |
350 Bar |
Maximum Pressure: |
400 Bar |
Operating Mode: |
Pump, Closed Circuit |
Series: |
1x And 3x |
Sizes: |
40 To 1000 |
Nominal Pressure: |
350 Bar |
Maximum Pressure: |
400 Bar |
Operating Mode: |
Pump, Closed Circuit |
Features
▶▶ Robust pump with very long service life
▶▶ Reduced noise
▶▶ Through drive for mounting of further pumps
up to same nominal size
▶▶ Flow direction changes smoothly when the swashplate
is moved through the neutral position
▶▶ Axial and radial load capacity of the drive shaft
▶▶ Modular design
▶▶ Visual swivel angle indicator
▶▶ Short response times
▶▶ Operation on HF-fluids under reduced operational
data possible
▶▶ Swashplate design
Hydraulic fluids
The A4VSG variable pump is designed for operation with
HLP mineral oil according to DIN 51524.
Application instructions and requirements for hydraulic
fluids should be taken from the following data sheets
before the start of project planning:
▶▶ 90220: Hydraulic fluids based on mineral oils and
related hydrocarbons
▶▶ 90221: Environmentally acceptable hydraulic fluids
▶▶ 90222: Fire-resistant, water-free hydraulic fluids
(HFDR/HFDU)
Notes on selection of hydraulic fluid
The hydraulic fluid should be selected so that the operating
viscosity in the operating temperature range is within the
optimum range (νopt see selection diagram).
Filtration of the hydraulic fluid
Finer filtration improves the cleanliness level of the hydraulic
fluid, which increases the service life of the axial piston unit.
A cleanliness level of at least 20/18/15 is to be maintained
according to ISO 4406.
At a hydraulic fluid viscosity of less than 10 mm²/s (e.g. due
to high temperatures during short-time duty) at the drain
port, a cleanliness level of at least 19/17/14 according to
ISO 4406 is required.
For example, the viscosity corresponds to 10 mm²/s:
– at a temperature of 73 °C for HLP 32
– at a temperature of 85 °C for HLP 46
Type code