Rexroth A4VSG500 Control Code Quick Guide
1. Product Basics
All codes below are size 500 cm³/rev from the A4VSG family — a swashplate, variable‑displacement axial piston pump for closed‑circuit hydrostatic drives.
Typical ratings for A4VSG500:
Nominal pressure: 350 bar
Maximum pressure: 400 bar
Max. speed at Vg max: ≈ 2000 rpm
Theoretical flow at n nom, Vg max: ≈ 1000 L/min
Approx. weight: ~235 kg
The A4VSG family covers sizes 40–1000, offering high power density, long service life, and optional through‑drive mounting of same‑size units.
2. Control Code Definitions
Code | Control Type | Description & Typical Use |
|---|---|---|
MA | Manual control | Mechanical handwheel/lever adjusts swashplate. No external pilot or electrical signals. Used for basic setups, testing, or where manual adjustment is acceptable. |
EO | Electrohydraulic electronic proportional | Current‑input proportional control of swashplate via solenoid valve. Sub‑variants EO1, EO2"indicate different generations or interface options (e.g., connector type, feedback signal). Allows precise electrical command of displacement with failsafe features." |
EO…K | EO control with “K” option package | The K suffix denotes a specific interface/accessory set (special electrical connector, pre‑wired harness, extra ports). Exact content defined in type code and data sheet — must match application needs. |
EP | Electrical proportional control | Similar to EO but often indicates a different valve stage or control characteristic (sometimes higher dynamics or different failsafe). Provides electrically commanded swivel‑angle control. |
HD | Hydraulic control (pilot‑pressure related) | Proportional control via hydraulic pilot signal. Sub‑variants include HD1, HD1D, "HD2", HD3, etc., differing in valve arrangement, pilot‑pressure range, and interface options. Used where hydraulic command signals are preferred. |
AA4VSG | Plug‑in variant for gearbox integration | “AA” prefix indicates a plug‑in version of A4VSG, designed for direct mounting into mechanical gearboxes with recessed flange. Functionally identical in control options but optimized for space‑saving integration. |
3. Meaning of Suffixes & Variants
MA – Manual adjustment only; simplest control method.
EO1 / EO2 – Electronic proportional; generation/interface differences.
K – Option package (connector, wiring, extra ports). Verify exact definition in data sheet.
EP – Electrical proportional (different valve stage/response from EO).
HD – Hydraulic pilot‑pressure control (with possible sub‑variants HD1, HD2, HD3 for different pilot ranges/features).
AA4VSG – Plug‑in version for gearbox mounting; otherwise same control choices as standard A4VSG.
Full type code structure:
A4VSG 500 <Control><Variant>/<Series>‑<Rotation>‑<Interface/Suffix>
Examples of known variants:
A4VSG500MA/30R‑PPB10N009NA4VSG500EO1K/30R‑PZB10K840NA4VSG500EO2/30R‑PPB10N009NA4VSG500EO2K/30R‑PKD60K249NA4VSG500EP/30R‑PPB10N009NA4VSG500HD/30R‑PPB10N009NAA4VSG500MA/30R‑PPB10N009NSeries (/30) and rotation (R/L/W) must match drive direction and mounting.
Interface suffix defines flange, ports, shaft, sealing, and through‑drive options (small differences change port standard or seal material).
4. Selection & Ordering Notes
Choose MA for simple manual setup/testing; EO/EP for precise electrical control; "HD" for hydraulic pilot‑pressure control; AA4VSG for plug‑in gearbox integration.
The K suffix modifies the base control with a specific accessory/interface package — verify its exact meaning in the data sheet or with your supplier.
Ensure series, rotation, and interface suffix exactly match your mechanical/hydraulic interfaces.
A4VSG pumps are for closed‑circuit drives; for open‑circuit applications, consider A4VSO or A4VG families.
Always confirm complete type code against nameplate and latest data sheet before ordering — availability and lead time vary by region and variant.