Rexroth A4VSG500 control code quick guide
1. Model basics and key specs for size 500
All codes below are size 500 cm³/rev from the A4VSG family — a swashplate, variable‑displacement axial‑piston pump for closed‑circuit hydrostatic drives.
Typical ratings for A4VSG500:
Nominal pressure: 350 bar
Maximum pressure: 400 bar
Max. speed at Vg max: approx. 2000 rpm
Theoretical flow at n nom, Vg max: approx. 1000 L/min
Approx. weight: ~235 kg
The A4VSG family spans sizes 40–1000, offering high power density, long service life, and optional through‑drive mounting of same‑size units.
2. Control code definitions for these variants
Code | Control type | Description & typical use |
|---|---|---|
HD | Hydraulic control (pilot‑pressure related) | Proportional control via hydraulic pilot signal. Sub‑variants: HD1, HD1D, HD1T, HD2T, HD3 etc. Differences include valve arrangement, interface options (e.g., “D” = with U‑version interface, “T” = with special trim or feedback), and pilot‑pressure range. Used where hydraulic command signals are preferred. |
HS | Electrohydraulic control (servo/proportional valve, speed/valve‑based regulation) | Position/speed control via electrohydraulic valve. Sub‑variants: HS1, HS4, HSK, HS4K, HS4M, HS4P etc., indicating interface, feedback, and valve‑stage differences. Suited for high‑performance closed‑circuit drives needing precise speed or displacement control. |
DR | Pressure and flow control (hydrostatic) – sometimes called “constant pressure/constant flow” | Swashplate controlled by differential pressure between load and control pressure. Often used for simpler load-sensing or constant-flow applications in closed circuits. |
DRG | DR control with additional “G” option | Typically means DR control plus an extra feature (often a flushing or boost valve arrangement). Exact function depends on series and suffix; verify with data sheet. |
3. Meaning of suffixes and sub‑codes
HD1 – Basic hydraulic control version.
HD1D – HD1 with "D" variant interface (often U‑version with extra ports or electrical feedback).
HD1T – HD1 with “T” trim/feedback (may include stroke limitation or special damping).
HD2T – Second‑generation hydraulic control with "T" trim/feedback.
HD3 – Third‑generation hydraulic control variant (different valve geometry or pilot range).
HS1 – First‑generation electrohydraulic speed/valve control.
DR – Pressure/flow hydrostatic control.
DRG – DR control with added "G" option (often flushing/boost valve).
Suffixes like /30R, /30L, /30W indicate series (commonly /30 for size 500) and rotation (R = clockwise, L = counterclockwise, W = reversible view). Final segments (e.g., ‑PPB10N009N, ‑PZB10K840N) define mounting flange, ports, shaft, sealing, and through‑drive options.
4. How to read and complete the full type code
General format:
A4VSG 500 <Control><Variant>/<Series>‑<Rotation>‑<Interface/Suffix>
Example full codes (known existing variants in distribution):
A4VSG500HD1/30R‑PPB10N009N
A4VSG500HD1D/30R‑PKD60K249N
A4VSG500HD1T/30R‑PZB10K840N
A4VSG500HD2T/30R‑PPB10N009N
A4VSG500HD3/30R‑PPB10N009N
A4VSG500HS1/30R‑PPB10N009N
A4VSG500DR/30R‑PPB10N009N
A4VSG500DRG/30R‑PZB10K840N
Always match series, rotation, and interface suffix to your mechanical/hydraulic interface; small differences in suffix change port standard, seals, or options.
5. Selection and ordering notes
Choose HD for hydraulic pilot‑pressure control, HS for electrohydraulic closed-loop speed/position control, DR/DRG for simpler hydrostatic pressure/flow control.
Ensure series (e.g., /30 common on size 500), rotation, and interface suffix exactly match your system requirements.
A4VSG pumps are for closed‑circuit drives; for open‑circuit applications, consider A4VSO or A4VG families.
Verify the complete type code against the nameplate and latest data sheet before ordering — availability and lead time vary by region and variant.