Rexroth A4VSG125 Control Code Quick Guide
(All models are size 125 cm³/rev, closed-circuit hydrostatic pumps)
1. Product Basics
The A4VSG125 is a swashplate, variable‑displacement axial piston pump from the A4VSG family, designed for closed-circuit drives in mobile and industrial applications. Key specs for size 125:
Nominal pressure: 350 bar | Max pressure: 400 bar
Max speed at Vg max: ≈ 2600 rpm | Flow at n nom: ≈ 325 L/min
Typical series: /30 (common for size 125)
Features: Integrated boost pump, high-pressure relief valves (charge valves), pressure cut-off, through-drive capability.
2. Control Code Definitions
Code | Control Type | Description & Key Features |
|---|---|---|
HD1 | Hydraulic (pilot-pressure) | Base hydraulic control: Proportional displacement via hydraulic pilot signal; spring-centering. |
HD1D | HD1 + "D" variant | HD1 with "D" interface (e.g., U-version with extra ports/electrical feedback). |
HD1T | HD1 + "T" trim | HD1 with "T" trim (special damping, stroke limitation, or feedback for precision). |
HD2T | HD2 + "T" trim | Second-gen hydraulic control (HD2) with "T" trim (updated valve geometry + precision features). |
HD3 | Third-gen hydraulic control | Advanced hydraulic control with revised valve arrangement/pilot-pressure range. |
HS1 | Electrohydraulic (speed-regulated) | Electrohydraulic control: Servo/proportional valve for speed/valve-based displacement regulation. |
DR | Hydrostatic pressure/flow control | Simple pressure/flow control via differential pressure between load and control circuits. |
DRG | DR + "G" option | DR control with "G" feature (typically flushing/boost valve for enhanced cooling/sealing). |
3. Model Code Structure
Format: A4VSG 125 <Control><Variant>/<Series>‑<Rotation>‑<Interface/Suffix>
Series (/30): Common for size 125.
Rotation (R/L/W): R = clockwise, L = counterclockwise, W = reversible (viewed on shaft end).
Interface suffix: Defines flange, ports, shaft, sealing, through-drive (e.g.,
-PPB10N009N,-PZB10K840N).
4. Examples of Known Variants
A4VSG125HD1/30R‑PPB10N009N– Base HD1 hydraulic control, standard interface.A4VSG125HD1D/30R‑PKD60K249N– HD1D with "D" interface (extra ports/feedback).A4VSG125HD1T/30R-PZB10K840N– HD1T with "T" trim (precision damping).A4VSG125HD2T/30R‑PPB10N009N– HD2T (second-gen + trim).A4VSG125HD3/30R‑PPB10N009N– Third-gen HD3 hydraulic control.A4VSG125HS1/30R‑PPB10N009N– HS1 electrohydraulic speed-regulated control.A4VSG125DR/30R-PPB10N009N– Basic hydrostatic pressure/flow control.A4VSG125DRG/30R-PZB10K840N– DRG with "G" option (flushing/boost valve).
5. Selection & Ordering Notes
Match control type to system needs: Use HD for hydraulic pilot control, HS for electrohydraulic speed regulation, DR/DRG for simple hydrostatic control.
Verify suffixes: Small differences (e.g.,
PPB10vsPZB10,N00vsK840N) change port standards, seals, or options—confirm with the nameplate/data sheet.Closed‑circuit only: A4VSG pumps are not for open-circuit use (choose A4VSO/A4VG for open circuits).
Ensure compatibility: Confirm series, rotation, and interface suffix match mechanical/hydraulic interfaces (flange, shaft, ports).
Always cross‑check the complete type code with Rexroth’s latest datasheet and the pump’s nameplate to avoid mismatches in control response, interfaces, or accessories.