Essential details
MOQ:Min. Order: 1 unit
Shipping:Express delivery, air freight, land transportation, sea freight
Product Introduction

Model Number Decoding: A10VO28DFR-31R-PPA12N00
A10VO:The series designation for Rexroth'sslant-axis design axial piston pumps. They are known for being more compact and cost-effective than the bent-axis A11VLO series, while still offering high performance. 28: The nominal displacement is 28 cc/rev (cubic centimeters per revolution). This is a small to medium displacement, ideal for auxiliary circuits, compact machinery, or systems requiring precise flow control. DFR:This is the critical control type identifier. It signifies a sophisticated, multi-function control: D (Druck = Pressure): Pressure Cut-Off / Limiter.The primary control. The pump operates in variable displacement mode until system pressure reaches a pre-set maximum, at which point it de-strokes to maintain that pressure, minimizing energy loss. F (Fluss = Flow): Flow Control.Acts as a load-independent flow regulator (LUDV principle). When active (e.g., via an electrical or hydraulic signal), it overrides the pressure cutoff and provides a fixed, pre-set flow rate regardless of load pressure changes, perfect for synchronous movements. R (Remote):Signifies that the pressure cutoff (D) setting can be adjusted remotelyvia a proportional pressure signal (typically 0-20 mA or similar). This allows for electronic control of the system's maximum pressure.
31R: The rotation direction is counter-clockwise when viewed from the shaft end. PPA12N00: This complex suffix defines the physical configuration. It specifies the mounting flange (e.g., SAE or ISO standard), the location and type of ports (pressure, tank, case drain, control lines), and the shaft type (e.g., splined or keyed). The N00often indicates a specific standard configuration. This code is essential for mechanical interchangeability.
Key Features & Technical Characteristics
Variable Displacement, Slant-Axis Design: Efficiently varies output flow (0 to 28 cc/rev) based on the DFR control signals. The slant-axis design offers an excellent balance of performance and compactness. Intelligent DFR Control: This is the pump's core intelligence. Default Mode (Pressure Cut-Off): Operates as a standard pressure-compensated pump, delivering flow on demand until the set pressure is reached. Flow Control Mode: When the electrical solenoid on the "F" control is activated, it provides a constant, precise flow for functions like tool rotation, feed drives, or cooling circuits. Remote Pressure Control: The system's maximum pressure can be controlled electronically, enabling power management modes (e.g., high pressure for breaking, lower for travel).
High Working Pressure: Typically rated for continuous operation up to 280 bar (≈4,060 psi) and higher peak pressures, making it robust for its size. Through-Drive Capability:Can be configured to drive a second pump (e.g., a gear pump for steering or pilot supply) from its rear end, saving space and complexity. Compact Design: The A10VO series is renowned for its high power density, making it ideal for applications where installation space is limited.
Primary Applications
Mobile Machinery: Compact Excavators & Wheel Loaders: For tool circuits (breaker, auger, grapple), fan drives, and swing functions. Aerial Work Platforms (AWPs): Lifting and extension functions where smooth, controlled movement is critical. Street Sweepers & Municipal Vehicles:For broom drives, conveyor systems, and water pumps. Agricultural Machinery: For feeder houses, conveyor adjustments, and auxiliary functions on harvesters.
Industrial Machinery: Machine Tools:For hydraulic clamping, indexing tables, and tool changers (often using the flow control feature). Plastics Injection Molding Machines:For core-pull circuits, ejectors, or accumulator charging. Test Stands & Simulators:Where precise and repeatable hydraulic power is needed. Material Handling:For pushers, lifters, and rotating devices on automation lines.
Selection & Maintenance Considerations
Control Understanding:Properly integrating the DFR control requires understanding its three modes. The electrical solenoid for flow control and the analog signal for remote pressure adjustment must be correctly plumbed and wired per the schematic. Fluid Cleanliness:As with all high-pressure piston pumps,ultra-clean fluid (ISO 4406 18/16/13 or better) is non-negotiable for long service life. Case Drain Line: The case drain (L) port must have a clean, low-restriction line directly to the tank. Pressure in this line should remain very low (typically < 2-3 bar). Consult Official Documentation:Always refer to the Rexroth technical data sheet (RE 92701 for A10VO series) and the specific characteristic curve diagram for the exact DFR/31R...control code. This is vital for setting control parameters and predicting performance.Seal Compatibility: Standard seals (as indicated in the code) are for mineral oil (HLP). For other fluids (like HETG or HFDR), the seal material (e.g., FKM/Viton) must be confirmed.
Summary




Image uploading.....