Rexroth A4VTG071 Variable Displacement Axial Piston Pump – Control Code Quick Guide
1. Product Overview
The A4VTG071 is a swashplate-type, variable-displacement axial piston pump from Rexroth’s A4VTG series, designed for closed‑circuit hydrostatic drivesinmobile machinery (especially concrete mixers) and other heavy-duty applications.
Displacement: 71 cm³/rev
Nominal pressure: 400 bar
Maximum pressure: 450 bar
Circuit: Closed circuit
Series: 33 (for sizes NG71/90)
Features:Integrated boost (charge) pump, two high-pressure relief valves (also serve as charge valves), pressure cut-off, through-drive capability.
2. Control Code Definitions for Listed Variants
Code | Control Type | Description & Key Features |
|---|---|---|
EP3 | Electro-proportional | 12 V DC solenoid, spring return with emergency actuation. Precise electrical control of swashplate angle. |
EP4 | Electro-proportional | 24 V DC solenoid, spring return with emergency actuation. Same function as EP3 but for 24 V systems. |
P0 | Interface suffix | Standard version without additional electrical interface beyond the control solenoid. |
PT | Interface suffix | Pump with control interface/adapter; commonly supplied with AZ‑P‑F‑12(12-pin plug kit) for external wiring. |
HD3 | Hydraulic control | Three‑position hydraulic control (valve‑actuated), pilot‑pressure related. Used for simple directional and displacement control via hydraulic signals. |
HW1 | Hydraulic/mechanical servo | Mechanical or hydraulic servo control; many catalog entries shorten to HW. |
HW10M / HW10T | HW1 variants | Specific design/interface variants within HW1 family. The exact difference (M vs T) is defined by the full type code and relates to mounting, valve arrangement, or accessory options. Must verify against data sheet/nameplate. |
3. Model Code Structure
General format:
A4VTG 071 <Control><Voltage>/<Series>‑<Rotation>‑<Interface/Suffix>
Examples of full codes matching your list:
A4VTG071EP3P0/33MRNC4C92F0000AS-0 → EP3 control, 12 V, standard interface.
A4VTG071EP3PT/33+AZ-P-F-12 → EP3 control, 12 V, with 12-pin interface kit.
A4VTG071EP4P0/33MRNC4V92F0000AS-0 → EP4 control, 24 V, standard interface.
A4VTG071EP4PT/33+AZ‑P‑F‑12 → EP4 control, 24 V, with interface kit.
A4VTG071HD300/33MRNC4C92F0000AS‑0 → HD3 hydraulic control.
A4VTG071HW100/33MRNC4C92F0000AS‑0 → HW1 hydraulic/mechanical servo control.
A4VTG071HW10M/33… → HW1 variant M.
A4VTG071HW10T/33… → HW1 variant T.
Series (/33) for sizes NG71/90.
Rotation(R/L) andinterface suffix define flange, ports, shaft, sealing, through‑drive.
P0 = no extra electrical interface; PT = with interface kit (AZ‑P‑F‑12 common for 12‑pin).
4. Selection Guidance
EP3 → Use with 12 V DCcontrol systems.
EP4 → Use with 24 V DCcontrol systems.
P0 → When no external electrical interface is needed (control integrated or hard‑wired).
PT→ When a detachable electrical connector/interface is required (e.g., for harness flexibility).
HD3 → For hydraulic pilot-pressure control; no electrical command needed.
HW1 (and HW10M/HW10T) → For mechanical or hydraulic servo control; chosen for simplicity or where electrical control is not used.
Always match complete type code (including series, flange, ports, suffix) to nameplate and machine parts list.
5. Application Notes
Primarily for closed‑circuit drives in mobile concrete mixers and similar equipment.
Built-inboost pump supplies pilot/control oil; charge pressure limited by internal relief.
Twohigh-pressure relief valves protect pump and motor in closed circuit; also function as charge valves.
Pressure cut-off standard to limit max system pressure.
Observe venting, case drain, and suctionrequirements during installation.
Do not interchange P0 vs PT or HW10MvsHW10T without confirming exact variant definition in official Rexroth documentation.
Summary:
Your listed A4VTG071 codes cover electro-proportional (EP3/EP4) and hydraulic/mechanical servo (HD3/HW1)controls, withP0 (standard) or PT (with interface) suffixes. Correct selection depends on control voltage,need for electrical interface, and hydraulic vs mechanical actuation preference. Always verify the full type code against the pump nameplate and datasheet before ordering.