Product Overview
The A10VSO100 Series 31 is a high-pressure, variable-displacement axial-piston pump for open-circuit hydrostatic drives. It is widely used in excavators, wheel loaders, and industrial machinery, delivering smooth, stepless flow proportional to drive speed and displacement with fast response and low noise. Rated for 280 bar continuous and up to 350 bar peak, the unit features ISO 3019‑1/SAE mounting flanges, two case drain ports, excellent suction performance, and a power-to-weight ratio optimized for mobile and stationary applications.
Key Specifications
Item | Specification |
|---|---|
Displacement (Vg) | 100 cm³/rev |
Nominal pressure (pnom) | 280 bar |
Maximum pressure (pmax) | 350 bar |
Intermittent pressure (10% duty) | 315 bar |
Inlet pressure (S port, abs) | 0.8–30 bar |
Case drain max pressure | ≤ 2 bar abs and ≤ S + 0.5 bar |
Recommended viscosity (Vopt) | 16–36 mm²/s (ISO VG46–VG68 typical) |
Allowable temp. range | –25°C to +90°C (fluid) |
Max. speed (size 100) | Typically 2100–3000 rpm (depends on version and options) |
Control options | DR, DFR/DFR1, DRG, DFLR, DG, ED, FHD |
Mounting / ports | ISO 3019-1 2-bolt (A/B), SAE J744 flanges, SAE J518 ports |
Through-drive | Up to same size (100%) for tandem/auxiliary pumps |
Notes: Speed capability varies by version (standard vs. high‑speed) and control; always verify against the selected variant’s data sheet. Pressure data per DIN 24312.
Typical Applications
Excavators and wheel loaders (implement/boom/arm circuits, pilot and fan drives)
Mobile hydraulic systems and industrial machinery requiring variable flow/pressure control
Open-circuit systems where high efficiency, low noise, and long service life are priorities
Model Code and Example
Example: A10VSO100DFLR/31R‑PPA12N00
Breakdown: A10VSO = variable axial piston pump; 100 = displacement; DFLR = pressure/flow/power control; 31 = series; R = clockwise rotation; P = seal material; P = keyed shaft; A = ISO 2‑hole flange; 12 = SAE metric ports; N00 = no through-drive.
Common variants: A10VSO100DR/31R‑PPA12N00, A10VSO100DFR1/31R-PPA12N00, A10VSO100DRG/31R‑PPA12N00, A10VSO100FHD/31R-PPA12N00.
Popular OEM cross-references include: R910920847, R910922744, R902544825, R910934823 (verify fitment with your machine’s build list/SN).
Installation and Maintenance Essentials
Perform full system flush; pre-fill pump and lines to remove air. Ensure correct rotation direction and that the case drain returns directly to tank with backpressure ≤ 0.05 MPa; avoid check valves on the case drain line.
Maintain recommended suction conditions: absolute inlet pressure ≥ 0.8 bar, keep within 16–36 mm²/s viscosity at operating temperature; the highest point in the system must not exceed 90°C.
Use clean hydraulic fluid; target NAS1638 Class 9 / ISO 4406 18/15 cleanliness or better.
Do not exceed maximum allowable speeds; respect tightening torques and porting per data sheet.
Safety: This pump is for open-circuit use; provide an external system relief valve for overpressure protection. Planning, assembly, and commissioning must be performed by qualified personnel.