Hydraulic fault diagnosis and maintenance of cylindrical grinder

Hydraulic fault diagnosis and maintenance of cylindrical grinder

The worktable of mq1350a cylindrical grinder crawls, the surface roughness of the workpiece is high, and it is fish scale, and there are irregular wavy lines, which brings great losses to the manufacturer. According to the use of this hydraulic equipment, fault history and current situation and other related factors, we use logic diagnosis method to eliminate the grinding machine crawling phenomenon. Starting from the fault phenomenon, the following procedures should be followed: making hypotheses for the problems raised, taking measures for hypotheses, checking whether the hypothesized results are tenable, drawing conclusions and handling.

(1) Diagnostic process

As shown in the table below.

 

Diagnostic process

Serial number

问题假设

措施

结果

1

操纵部位不灵敏

更换滑阀、开停阀、换向阀、进给阀、进退阀

经检查仍有爬行现象,假设不成立

2

系统压力过低或不稳定

检查阀类元件,将减压阀压力调至0.4~0.6MPa,工作台润滑油稳定器压力调至0.05~0.15MPa

运行过程中压力正常,假设不成立

3

系统其他部位有泄露

通电后,液压泵经溢流阀压力调至1~1.2MPa

卸荷状态进入工作状态,压力上升稳定,说明系统其他部位完好,假设不成立

4

滑动部件阻力不正常

对滑动部件进行调整,并加润滑油

检查无异常情况,假设不成立

5

液压缸与滑动部件安装不妥

调整液压缸及部件的正确性

经检查安装正确,无异常情况,假设不成立

6

吸油部分结构不合理,引起吸油困难

将吸油管、滤油器、液压泵拆开清洗并调整

运行时,此部分正常,假设不成立

7

管道,泵,阀,液压缸漏气

清洗、调整各部件,检查此部分是否漏气现象

系统工作后,未出现明显振动及噪声,此部分无漏气现象,假设不成立

8

密封件磨损,老化

更换液压缸密封件

更换密封件后,爬行稍有好转,但仍不能消除,假设成立

9

液压油不合格

利用放气阀在全行程内移动,排除系统内空气

每当工作台行至床身左端时,放气阀一端就产生气泡,爬行明显,快慢都是如此。假设成立

 

(2) Conclusion

The result from the diagnosis table is that the hydraulic oil is unqualified and the sealing ring is aging, which causes the hydraulic system of the grinder to crawl.

(3) Treatment

① Replace the seal ring. Because the material of the seal ring purchased in the market is not guaranteed, the service life of the seal ring is short and needs to be replaced frequently.

② Since the original used hydraulic oil is 20 ° engine oil, after using for a period of time, bubbles and crawling will be formed due to oil pollution and other factors. An32g anti creeping guide rail oil is now replaced. The oil is changed in strict accordance with the oil change standard. After the oil change, the creeping is eliminated after the inspection and test run.

After adopting the above treatment method, the surface roughness of the grinding workpiece meets the requirements and meets the production needs.

(4) Summary

There are many factors that cause the hydraulic system to crawl. The above measures are only a part of them. When the grinder is working, we should pay attention to other factors that cause the hydraulic system to crawl. When diagnosing the fault of hydraulic system, it is necessary to master the principle, structure and function of hydraulic components and hydraulic system correctly. During the diagnosis, the principle of "from the outside to the inside" (reducing blind disassembly) and "from the easy to the difficult" should be followed, so as to find out the root cause of the fault. Two problems should be paid attention to when putting forward various possible reasons

First, don't forget to list the possibility of faults of relevant electrical components (such as solenoid valve, relay, etc.) and eliminate them first; Second, before analyzing the key parts, we should determine whether the relevant peripheral conditions (environment) are normal. Adopting logic diagnosis method is very suitable for dealing with some problems of hydraulic equipment, which can ensure that the diagnosis work is carried out in an orderly way, improve the efficiency and accuracy, and improve the thinking ability and working method of maintenance personnel.